¿Es eficiente la protección anti radiación otorgada por gorros de pabellón de Tungsteno-Bismuto en cardiología intervencionista?
Palabras clave:
Endovascular Procedures, Occupational Exposure, Occupational Health, Radiation ProtectionResumen
Background: The effectiveness against radiation of Tungsten Bismuth caps, used in interventional cardiology is not well known. Aim: To determine the degree of radiation protection conferred by these caps in real work conditions. Material and methods: We compared the gross electric charges received at brain lobe levels by three occupationally exposed professionals who participated in 22 consecutive procedures, inside and outside of the Tungsten Bismuth cap. Results: The median electric charges outside and inside the cap were 3.71 (range 1.46-5.62) and 2.2 (range 1.29-3.93) nC, which correspond to a 40% radiation attenuation. However, the protection was heterogeneous. Conclusions: Tungsten Bismuth caps provide an adequate attenuation, but its degree is heterogeneous.Descargas
Publicado
2016-07-14
Cómo citar
Ramos-Avasola, S., Díaz, N., Roldan, R., Gamarra, J., & Catalan, M. (2016). ¿Es eficiente la protección anti radiación otorgada por gorros de pabellón de Tungsteno-Bismuto en cardiología intervencionista?. Revista Médica De Chile, 144(7). Recuperado a partir de https://revistamedicadechile.cl/index.php/rmedica/article/view/4739